Raritan Intelligent PDU Dominion PX

Dominion® PX

The Raritan PX family of high quality rack power distribution units (PDUs) offers real-time remote power monitoring of current (amps), voltage, power (kVA, kW) and energy consumption (kWH) with ISO/IEC +/- 1% billing-grade accuracy.


PRODUCT OVERVIEW

With the Dominion PX:

• Emergencies can be resolved with remote serial and TCP/IP access to outlet-level switching, improving MTTR.
• Capacity planning is simplified with unit-level and outlet-level power utilization information.
• Staff can gather detailed power information to improve uptime and productivity.
• Travel costs and time can be saved with remote power cycling and monitoring.

    Information provided by the Dominion PX - displayed at the strip via an LED display, and remotely through a Web browser - can be used to improve capacity planning through power consumption information for both the PDU and individual receptacle. Precise, outlet-level access and control allows users to reboot attached devices.

    Whether used alone or integrated with other Raritan solutions, the intelligent Dominion PX offers secure access with 256-bit AES encryption and strong passwords. Dominion PX supports advanced authorization options including outlet-level permissions and LDAP/S, RADIUS and Active Directory®. Flexible management interfaces support HTTP, HTTPS, IPMI, SMASH-CLP, SSH, Telnet and SNMP, as well as user-configurable, outlet-level delays for power-sequencing.

    Dominion PX Remote Power Management Solutions can be integrated with the following Raritan solutions:

    • KVM switches: Dominion® KX II and Paragon® II
    • Secure console servers: Dominion SX
    • Centralized IT infrastructure management: CommandCenter® Secure Gateway

       
      VACOutletsRack UnitsAmps Per Phase
      162030325060
      12081DPXR8-15
      DPCR8-15-J
      DPXR8-20
      DPXR8-20L
      PX-5812
      12012ZeroDPXS12-20
      DPXS12-20L
      DPCS12-20L-J
      DPCS12-30L
      DPXS12-30L
      DPCS12-30L-J
      12020ZeroDPCS20-20
      DPXS20-20
      DPXS20-20L
      DPXS20-20L-J
      DPXS20-30L
      DPCS20-30L-J
      120202DPXR20-20
      DPXR20-20L
      DPXR20-30L
      12024ZeroPX-5802T
      3PH
      120/
      208
      24ZeroPX-5652
      3PH
      120/
      208
      30Zero
      20862PX-5810
      20881DPXR8A-20L6
      DPCR8A-20L6-J
      PX-5198
      20816ZeroPX-5384
      20820ZeroDPXS20A-20L6DPCS20A-30L6
      DPXS20A-30L6
      DPXS20A-30L6-J
      PX-5464
      PX-5464T
      208202DPXR20A-20L6DPXR20A-30L6
      20824ZeroPX-5496
      23081DPXR8A-16
      23012ZeroDPXS12A-16DPXS12A-32
      23016ZeroPX-5367PX-5397
      23020ZeroDPXS20A-16DPXS20A-32
      PX-5469T, PX-5469
      230202DPXR20A-16DPXR20A-32
      23024ZeroDPXS24A-16T

      240

      81DPXR8A-20AU
      24012ZeroDPXS12A-20AUDPXS12A-32AUA
      24016ZeroPX-5820
      PX-5820A1
      PX-5820A2
      24020ZeroDPXS20A-20AUDPXS20A-32AUA, PX-5469A2T
      24024ZeroPX-5635PX-5501
      3PH 20862PX-5119
      3PH
      208
      18ZeroPX-5902T
      3PH
      208
      24ZeroPX-5508PX-5520
      PX-5522, PX-5523
      PX-5524
      PX-5525
      PX-5532
      PX-5534
      PX-5535
      3PH
      230
      122UPX-5301
      3PH
      230
      24ZeroPX-5551
      3PH
      400
      12ZeroPX-5314
      PX-5315
      PX-5616PX-5318
      PX-5318A2
      3PH
      400
      18ZeroPX-5906T
      3PH
      400
      24ZeroPX-5630
      PX-5633
      PX-5528
      PX-5530

       

      FEATURES & BENEFITS

      Features

      Benefits

      Power Distribution
      Power Sequencing
      (User Defined)
      In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.)
      Receptacle Status RetentionIn the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets.
      Circuit BreakersThe PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user.
      Power Monitoring
      Power MeteringThe PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level.
      AlertingIn case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur.
      Overload AlarmUser-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services.
      Environmental MonitoringThe PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling.
      Seven-Segment LED DisplayShows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles.
      Remote Access
      IP Auto Configuration with DHCP, BOOTPEasy setup and administration.
      Flexible Remote Access Options Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:
      • Convenient HTML GUI
      • Server Management Interface (IPMI)
      • Network Management Interface (SNMP)
      • UNIX®-like console interface via serial connector or TELNET/SSH (compatible with SMASH server management)
      Dynamic DNS SupportUsers can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name.
      IPMI and SMASH CLPThe first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU.
      Power Management
      HTML User InterfaceThe PX's intuitive browser-based GUI enables remote energy management.
      Outlet GroupingWhen using PX models which support switching in a stand-alone mode over TCP/IP, users can define multiple outlets across multiple PDUs to function as a single virtual outlet. This is useful for powering down and rebooting servers with redundant power supplies.
      Virtual OutletsFor PX models that support switching, outlets on multiple PX units can be grouped for ease of management and administration of servers.
      Integration with Multiple Raritan SolutionsSimplified power control capabilities, power on/off/recycle, is available through Raritan's Dominion KXII, Dominion SX, Paragon® II, and CommandCenter® Secure Gateway 3.1.1 or higher, providing systems administrators access to power control via one­user interface.
      Security
      Up to 256-bit AES Encryption The PX is the first and only PDU in the industry that supports 256-bit AES encryption.
      SSL CertificateCreating individual server side SSL certificates enhances the security level of PX.
      Event LoggingTracks user logins, logouts, and power activities for an audit trail to support regulatory compliance.
      Local and Remote Authentication and AuthorizationPX provides built-in support for standards-based authentication protocols, including LDAP/S, RADIUS, and Active Directory. When deployed in conjunction with other Raritan solutions, additional authentication schemes can be supported, including TACACS+, Kerberos, and SecureID.
      User-Rights Per OutletAn administrator can assign permissions on an outlet level to prevent unauthorized access.
      Hardware Features
      Vertical and Horizontal Rack Mount ModelsPX units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames.
      Integration with Industry-Leading RacksEasy integration and support for up to 5 different mounting positions in industry-leading racks.
      ConnectionsSerial RJ-12 for environmental probes, RJ-45 for serial access/Power-CIM, RJ-45 Ethernet 10/100Base-T. Link status, network activity, and 10/100 status LED. Full support for full-duplex and 100Mbps operation.
      Receptacle Status LEDIndividual LED indicator at each receptacle allow for quick and easy status checks at the rack.
      Flexibility of ConnectionsSimultaneous connection via Ethernet (TCP/IP) and serial ports for advanced applications and redundancy of connections.